IP65 LED Lampu Darurat IP 65 LED 2FT 4FT
LL02H210 (Standar)
LL02H218 (Standar)
LL02I210 (Darurat)
LL02I218 (Darurat)
LL02J210 (Darurat + Sistem Pemanasan)
LL02J218 (Darurat + Sistem Pemanasan)
Fitur Utama
Perumahan dijieunna tina serat gelas poliéster bertulang (GRP)
Diffuser PC transparan sareng tahan dampak anu luhur
Modeu standar sareng darurat sayogi
Sistem pemanasan otomatis pikeun operasi dina suhu anu tiis pisan dugi ka -40 ° C
IP65
Item Spésifikasi. | LL02H210 | LL02H218 | LL02I210 | LL02I218 | LL02J210 | LL02J218 |
Kodeu | LL02H210-6 | LL02H218-6 | LL02I210-4/6 | LL02I218-4/6 | LL02J210-4/6 | LL02J218-4/6 |
Item GE No. | 445W2449P001 (120-230V), 445W2449P004 (100V)445W2449P006 (120-230V) | 452W5645P001(1 kelenjar kabel)452W5645P002(2 kelenjar kabel) | 445W2449P002 (120-230V),445W2449P005 (100V)445W2449P007 (120-230V) | 445W2449P003 (120-230V) 445W2449P008 (120-230V) | 452W5645P003(1 kelenjar kabel)452W5645P004(2 kelenjar kabel) | |
Katerangan | Lampu, LED, Standar SW/CW | Lampu, LED, Cadangan Darurat, SW | Lampu, LED, Cadangan Darurat, Sistem Pemanasan, CW | |||
Tegangan Input | 120-277V | |||||
Rentang tegangan | 100-300V | |||||
Frékuénsi | 50-60Hz | 50-60Hz | 50-60Hz | 50-60Hz | 50-60Hz | 50-60Hz |
Daya Input Dipeunteun | 23W | 45W | 23W | 45W | 23W | 45W |
30.5W (Gawé Sistem Pemanasan) | 52.5W (Gawé Sistem Pemanasan) | |||||
Arus Nominal | 0.19A | 0.38A | 0.19A | 0.38A | 0.19A | 0.38A |
0.26A | 0.44A | |||||
Suhu Operasi. | -35~55°C | -35~55°C | -5~55°C | -5~55°C | -35~55°C | -35~55°C |
Survival Temp. | -40~60°C | -40~60°C | -15~60°C | -15~60°C | -40~60°C | -40~60°C |
Jenis Lampu | LED SMD, Tiis Bodas | |||||
Kaluaran Lumén | 2100lm | 3700lm | 2100lm | 3700lm | 2100lm | 3700lm |
Waktos Darurat | N/A | N/A | > 90 mnt | > 90 mnt | > 90 mnt | > 90 mnt |
Batré Hirupna | N/A | N/A | 5 taun | 5 taun | 5 taun | 5 taun |
Meas.Tina pencahyaan | L 670mm x W 164mm x H 102mm | L 1275mm x W 161mm x H 102mm | ||||
Jarak pamasangan | 400±5mm | 984±5mm |
** Kode No LL02H210-X, nalika X = 2: CE disatujuan;X=4: UL disatujuan;X = 6: CE + UL disatujuan.
LL02H210/LL02I210/LL02J210:
jarak ningkatna (LF): 400 ± 5mm 2pcs ningkatna liang siap pikeun bolts M6.
LL02H218/LL02I218/LL02J218:
Solusi Pasang 1
jarak ningkatna (LF): 984 ± 5mm 2pcs ningkatna liang siap pikeun bolts M6.
Solusi Pamasangan 2
jarak ningkatna (LF): 800 ± 5mm 2pcs ningkatna liang siap pikeun bolts M6.
Ilustrasi dipasang:
Nomer Bagian Phenix | Nomer Bagian GE | Jumlah kelenjar | Lokasi kelenjar | Jumlah colokan dummy |
LL02H210/LL02I210/LL02J210 | 445W2449P001-445W2449PP005 | 2 | Dina tungtung padeukeut toe silih | 1 |
LL02H210 / LL02I210 / LL02J210 | 445W2449P006-445W2449P008 | 3 | Dua dina tungtung padeukeut jeung lianna. Katilu dina tungtung sabalikna tina dua kelenjar séjén | 0 |
LL02H218/LL02I218/LL02J218 | 452W5645P001/452W5645P003 | 1 | Dina tungtung deukeut blok terminal | 0 |
LL02H218/LL02I218/LL02J218 | 452W5645P002/452W5645P004 | 2 | Hiji dina unggal tungtung | 0 |
1 (atanapi 2) kelenjar kabel dina hiji sisi
1 atawa (0) kelenjar kabel dina sisi séjén
Klip henteu murag
Sistem pemanasan dianggo pikeun mastikeun luminaire tiasa dianggo saé dina hawa anu tiis pisan dugi ka -40 ° C.
tegangan input: 120-277V
Pikeun lampu darurat (atanapi darurat + pemanasan), uji sareng pangropéa ieu kedah dilaksanakeun:
Pencét Pindah Tes LED (TSW) pikeun ngaganggu kakuatan pikeun ngarahkeun supir darurat sareng maksa lampu kana mode darurat, lampu strip LED ayeuna hurung dina lampu anu ngirangan;lampu sinyal LED (LSL) dina TSW pareum dina modeu darurat.Saatos ngabebaskeun TSW, luminaire balik deui ka operasi normal saatos reureuh sakedapan, lampu strip LED cahayana kalayan kakuatan pinuh, sareng LSL hurung.
Saklar Tés LED (TSW)
Catetan: Upami pangguna akhir peryogi luminaire pikeun asup kana modeu darurat ngan ukur nalika kakuatan listrik gagal, saklar éksternal kedah ditambah dina terminal input.
Saatos masang saklar éksternal, luminaire kedah diuji (dua status hurung sareng mareuman) upami saluyu sareng kaayaan di handap ieu:
Nalika kakuatan listrik hurung:
Hurungkeun saklar éksternal, luminaire dina modeu normal: Sadaya lampu strip LED hurung, sarta LSL hurung, sarta batréna keur dicas.
Pareuman saklar éksternal, luminaire dina modeu normal: sadaya lampu strip LED pareum, LSL hurung, sareng batréna nuju dicas.
Nalika suplai listrik gagal:
Henteu masalah lamun switch éksternal dihurungkeun atawa mareuman, luminaire balik kana modeu darurat.Kabéh lampu strip LED cahayana dina kaluaran ngurangan.LSL pareum sareng batréna nuju discharged.
1.Tes Otomatis instan
Nalika sistem disambungkeun ogé tur diaktipkeun, luminaire bakal otomatis nguji lamun beban sarta pak batré disambungkeun ogé sarta lamun batré keur dicas normal.Upami aya kaayaan anu teu normal, Lampu Sinyal LED (LSL) kedip-kedip.Nalika abnormity dihapus, LSL nunjukkeun normal.
2.Preprogrammed dijadwalkeun Otomatis Test
- Laksanakeun Uji Otomatis bulanan munggaran saatos kakuatan awal hurung salami 24 jam dugi ka 7 dinten, saatosna, ngalaksanakeun Tes Otomatis bulanan unggal 30 dinten.
- Ngalaksanakeun Tes Otomatis taunan unggal 52 minggu saatos mimiti diaktipkeun.
- Timing Uji Otomatis
Pikeun ngurangan konflik nu Auto Test dieksekusi nalika lampu keur dipake, nu preprogrammed Auto Test dijadwalkeun bakal dieksekusi 2 jam engké ti operasi normal dipegatkeun (dipareuman).Pikeun aplikasi dimana lampu tetep bercahya, modul bakal nunda tes dijadwalkeun sasuai, tapi teu kudu engké ti preprogrammed dijadwalkeun waktu tés panganyarna.
- Uji Otomatis Bulanan
Uji Otomatis Bulanan kedah dilaksanakeun unggal 30 dinten sareng pikeun nguji:
Lamun switchover tina mode normal sarta darurat normal;
Upami fungsi darurat sareng kaayaan ngecas sareng ngecas batré normal;
Waktu Uji Otomatis sakitar 30 detik.
- Uji Otomatis Taunan
Tés Otomatis Taunan kedah dilaksanakeun saatos 24 jam ngecas pinuh sareng pikeun nguji:
Lamun tegangan batré urang sarua atawa leuwih luhur ti wates sanggeus 24 jam ngecas pinuh;
Upami waktos operasi darurat langkung ti 90 menit;
Lamun tegangan batré sanggeus 90 menit operasi darurat masih sarua atawa luhur batan 87,5% tina tegangan batré saméméh nguji.
– Dina mangsa Uji Otomatis, bisi aya pareum listrik sarta kakuatan teu bisa dihurungkeun nepi ka Tes Otomatis réngsé, maka Tés Otomatis bakal dieksekusi deui 24 jam engké sanggeus kakuatan hurung.
– Upami modeu darurat ngajadikeun batre dileungitkeun sapinuhna dina kaayaan pareum, maka Uji Otomatis anu dijadwalkeun anu tos diprogram bakal diteruskeun deui nalika listrik disambungkeun.
3. Tes Manual
- Pencét saklar uji LED (LTS) sakali, teras lebet kana modeu darurat sareng gancang deui ka modeu normal.
- Pencét LTS 2 kali terus-terusan dina 5 detik, teras lebet kana tés bulanan.Saatos réngsé, tés bulanan salajengna bakal diitung ti tanggal ieu.
- Pencét LTS 3 kali terus-terusan dina 5 detik, teras lebet kana tés taunan.Saatos réngsé, tés taunan salajengna bakal diitung ti tanggal ieu.
– Salila tés manual, pencét LTS 3 kali dina 5 detik, teras tés manual bisa terminated.(Waktos Uji Otomatis anu dijadwalkeun sateuacanna moal robih)
4. Indikasi Lampu Sinyal LED (LSL).
- LSL on: Normal
- LSL pareum: Kagagalan listrik
– LSL robah bertahap: Dina nguji
– LSL kedip-kedip: Abnormal
No. | Item No | Karton Luar L(CM) | Karton LuarW(CM) | Karton LuarH(CM) | Jumlah/CTN (PCS) | NW/CTN (KGS) | GW/CTN (KGS) | |
1 | LL02H210 | 70 | 37 | 25.5 | 4 | 16.5 | 18.2 | |
2 | LL02H218 | 130.5 | 37 | 25.5 | 4 | 19.8 | 21.3 | |
3 | LL02I210 | 70 | 37 | 25.5 | 4 | 17.7 | 19.4 | |
4 | LL02I218 | 130.5 | 37 | 25.5 | 4 | 20.8 | 22.3 | |
5 | LL02J210 | 70 | 37 | 25.5 | 4 | 18.5 | 20.4 | |
6 | LL02J218 | 130.5 | 37 | 25.5 | 4 | 21.5 | 22.8 |
Sistim kakuatan angin
Kapal
Freezers
Sakur lokasi jero ruangan sareng luar anu parah